<< Contents
<< Workbar
<< WorkBar Tabs
<< Trigger Tab
|
|
|
|
The Trigger Values in any TriggerForm must use hexadecimal or binary characters.
|
|
The "anything" character ("x") is also allowed except with Range Events.
|
|
However, the "?" ambiguous character may automatically appear in hexadecimal trigger values.
|
|
The ambiguous character represents ambiguous trigger values the match more than one input value..
|
|
But unlike the "anything" character, ambiguous trigger values do not match all input values.
|
|
The "?" character warns you the trigger should be viewed in binary rather than hexadecimal.
|
|
Each binary character represents 1 channel. Each hex character represents 4 channels. If you edit a trigger value in binary, set some channels to 0 or 1, leave other channels as "x", then switch to the hex display, the "?" character will be displayed for the ambiguous hex character.
|
|
The "?" character cannot be entered from the keyboard. The GoLogic7 software automatically displays this value when needed.
|
|
Copyright and trademark information
|
|