<< Contents << Workbar << WorkBar Tabs << Trigger Tab
 
Trigger Lines
 
Trigger Lines have one or more Trigger Events.
 
While on a Trigger Level, the logic analyzer compares the input signals against each Trigger Line in top-down order.
 
The topmost line is compared first. If the input signals do not match, then the next line is compared, and so forth.
 
When a Line matches the input signals, the logic analzyer executes the Line's Action.
 
The number of Trigger Lines allowed per level depends on the logic analyzer model.
 
The Appendices define each model's trigger limits.
 
As more trigger resources are used, the available lines on each level are reduced.
 
Line Edit Button
 
Click on "If" or "ElseIf" and select "New If/ElseIf", "Copy If/ElseIf", "Paste If/ElseIf Below", or "Paste If/ElseIf Above".
 
 
Timer / Counter
 
Triggers Lines can enable a local Timer / Counter.
 
Storage
 
If the Custom TriggerForm's Selective Storage option is "Store: Only Selected Lines", the Line Storage list box defines if the Line Events are stored to memory.
 
 
Action
 
The Action defines what happens when the Trigger Line matches the channel inputs.
 
 
Each Line's action can be...
 
 
Trigger
The logic analyzer stops running.
 
GoTo NEW Level
A new Trigger Level is automatically added to the Custom TriggerForm. The logic analyzer jumps to the new level.
 
GoTo Start
The logic analyzer jumps to the level #1.
 
GoTo Level N
The logic analyzer jumps to the specified level.
 
Start Global Timer / Inc Global Counter
The logic analyzer starts / increments the specified global timer / counter.
 
Copyright and trademark information